Archive

Posts Tagged ‘BACT Analysis’

The BACT Analysis Guide: EPA Proposes Permit and BACT Requirements for Greenhouse Gases

October 1st, 2009

On September 30, 2009 the EPA announced a proposed rule that sets permitting and Best Available Control Technology (BACT) requirements for large facilities that emit over 25,000-tons of greenhouse gases (GHG) per year.  The proposed rule has been titled “Prevention of Significant Deterioration and Title V Greenhouse Gas Tailoring Rule” and focuses on emissions of the following group of GHG:

  • Carbon Dioxide (CO2)
  • Methane (CH4)
  • Nitrous Oxide (N2O)
  • Hydrofluorocarbons (HFC)
  • Perfluorocarbons (PFC)
  • Sulfur Hexafluoride (SF6)

The EPA is proposing that the GHG emissions from facilities be estimated using carbon dioxide equivalents (CO2e), which is the international standard. This metric uses the global warming potential of gases other than CO2 to translate them into CO2e.

Under the Title V program (40 CFR part 70), facilities would be considered a major source if they emit greater than 25,000-tons/year of CO2e and would be required to obtain a Title V operating permit. Under the New Source Review (NSR) Prevention of Significant Deterioration (PSD) program, a new source, or major modification at an existing source, would be considered major if it emits greater than 25,000-tons/year of CO2e and would be required to obtain a PSD permit. Modifications at existing major sources resulting in CO2e emissions increases of 10,000-tons/year to 25,000-tons/year (the exact number has not yet been decided) would be required to obtain a PSD permit.

The facilities with GHG emissions that trigger the PSD permitting requirements would be required to perform a BACT Analysis and incorporate BACT to control GHG emissions from their facility. Facilities that may be subject to this proposed rule include: power plants, refineries, and municipal solid waste landfills. Small facilities such as farms and restaurants will not be subject to the proposed rule.

The BACT for Carbon Monoxide (CO) from many of these large facilities is an oxidizer (or incinerator). These devices control CO emissions by converting them into CO2. Under this new rule, a facility could be required to obtain a Title V or PSD permit due to the secondary emissions from their CO control device (i.e., without the control device they would not have to be permitted for their CO2e emissions). Furthermore, the same facility may be required to install BACT for GHG emissions. This could pose a great financial burden on facilities subject to this rule. One possible solution to this issue is that the EPA could allow that only primary CO2 emissions (not those generated during CO control) be included when comparing CO2e emissions with the GHG permitting threshold.

bmogan BACT Regulations , , , , ,

The BACT Analysis Guide: BACT for Coal Fired Power Plant

September 30th, 2009

A Best Available Control Technology Analysis (BACT Analysis) for this 385-MW coal fired power plant revealed that the BACT for SOx emissions was a scrubber and the BACT for NOx emissions was a selective catalytic reduction system (SCR). This video summarizes the project, located at Basin Electric Power Cooperative’s Dry Fork Station (currently under construction), and describes the technology behind the state-of-the-art reflux circulating fluid bed dry scrubber.

bmogan BACT Analysis , , ,

The BACT Analysis Guide: RSCR Technology for NOx Control

September 28th, 2009

For common applications, such as boilers and turbines, a Best Available Control Technology Analysis (BACT Analysis)typically must consider a Selective Catalytic Reduction (SCR) system as a potentially applicable technology for control of NOx. With the relatively recent (October 2004) industrial application of Babcock Power’s Regenerative Selective Catalytic Reduction (RSCR) system, a BACT Analysis that must consider SCR may likely require consideration of RSCR as well, especially for biomass fuel burning equipment.

SCR systems require a minimum temperature of approximately 575°F for the destruction of NOx. For applications where the process or equipment burns biomass fuels, a particulate control device is usually needed upstream of the SCR for it to function properly. However, by the time the flue gases pass through the particulate control device their temperature range is much less than required (between 57 and 61 percent) for the SCR to operate effectively. The traditional solution would be to install a natural-gas or oil fired burner between the SCR and particulate control device to re-heat the air to the appropriate temperatures. The economic burden of the capital costs associated with this control scenario, as well as the cost of the fuel required to operate the burners, is not cost effective given the amount of NOx removed.

As a solution, Babcock Power teamed with Pro-Environmental, Inc. (PEI) to combine Babcock’s SCR expertise with PEI’s Regenerative Thermal Oxidation (RTO) technology, capable of achieving heat recovery efficiencies of greater than 95 percent, to produce the RSCR technology. In 2005, a RSCR system installed at a 50MW power plant fired by wood and construction/demolition waste achieved a NOx emission rate of 0.07-lb/mmBTU. This emission rate equates to an 86% reduction in NOx emissions from wood waste combustion (AP-42 Chapter 1.6, Table 1.6-2 “Dry wood-fired boilers”).

If you would like more information on RSCR techology, visit Babcock Power’s website.

If you would like help completing your BACT Analysis, or any portion thereof, feel free to contact me.

bmogan BACT Analysis , , , , , ,

The BACT Analysis Guide: Technical Feasibility

July 2nd, 2009

After identifying all of the control technologies with the practical potential for application to the emission unit, the BACT Analysis proceeds with eliminating technically infeasible control scenarios. For the purposes of a BACT Analysis, a technically feasible control scenario is one that has been used in the “real world”. By this I mean that just because a professor at some university has developed an experimental device for controlling NOx from a biomass boiler doesn’t mean you have to consider it as a technically feasible control device in your BACT Analysis. However, if a control device is commercially available and has the practical potential to control emissions from your source, then you must consider it to be technically feasible and include it in your BACT Analysis.

According to the 1990 EPA NSR Workshop Manual, in order to show that a control scenario is technically infeasible you must “clearly document and show, based on chemical, physical, and engineering principles, that technical difficulties would preclude the successful use of the control option on the emission unit under review”.

Here is an example:

Our client wanted to install a 6-MW Biomass Boiler to supply process heat for the greenhouses at their facility. Because of the potential emissions from the proposed emission unit, our client was required to perform a BACT Analysis for PM, PM10, NOx, and CO.

One of the control devices identified for the control of particulate matter (PM and PM10) from the boiler was a fabric filter, also known as a baghouse. Although baghouses are used to control particulate emissions from biomass boilers, they are typically installed on larger units at facilities which have full-time boiler staff (1). If left unmonitored, burning cinders, temperature excursions, and/or operating upsets could result in a fire (2). Our client did not have a full-time boiler staff and therefore using a baghouse to control particulates from the proposed boiler was deemed technically infeasible.

If you have questions regarding the technical feasibility of the control technologies that you have identified, feel free to contact Brandon Mogan at 800-850-2348 ext. 6115, or click here for more information.

(1) Resource Systems Group, Inc.
(2) Hog Fuel Boiler RACT Determination. Washington State Department of Ecology. Doc. No. 03-02-009

bmogan BACT Analysis , , , , , ,

The BACT Analysis Guide: Identify Control Technologies

June 6th, 2009

The first integral step in the Best Available Control Technology Analysis (BACT Analysis) process, after determining which pollutants require BACT, is to identify ALL control technologies with the PRACTICAL POTENTIAL for application to the emission unit. It is important to understand that the term ”control technology” is any methodology or technology which will control emissions of the affected pollutant and may include, but is not limited to, the following:

  • Control Devices
  • Alternative source operating scenarios
  • Alternative fuel combustion techniques
  • Control technologies that have been applied to similar emission units

The list of potentially applicable control technologies should be comprehensive. It should include every control scenario from that which provides the most pollutant control (typically LAER) to that which provides the least pollutant control. When generating this list, one must consider all sources of information, including but not limited to:

  • EPA’s RACT/BACT/LAER Clearinghouse
  • EPA/State air quality permits
  • Federal/State air emission inventories
  • Control equipment vendors
  • Manufacturer’s and trade associations
  • International and foreign environmental agencies
  • Inspection/Performance test reports
  • Technical papers and journals
  • Pollution prevention resources

The process of identifying applicable control technologies is a tedious and in-depth process. There are, however, some on-line resources available that offer a good starting point for this purpose. The following is a review of some more commonly referenced sources for identifying control technologies.

EPA’s RACT/BACT/LAER Clearinghouse

The Environmental Protection Agency’s (EPA’s) RACT/BACT/LAER Clearinghouse (RBLC) is a database of best available control technologies that have been applied to reduce emissions of air pollutants. As seen below, it is set up in a very user friendly fasion:

RBLC Database Search

RBLC Database Search

This image is of a “find lowest emission rate” search for carbon monoxide (CO) emissions from a commercial size wood-fired boiler. This search results in the following results:

RBLC Database Search

RBLC Database Search

From this search we have identified two different facilities which have applied best available control technologies for carbon monoxide emissions from their wood-fired boilers. To get more information about the type of control technology, the user must simply click on the “create report” button.

From project experience, I have found that the RBLC is very incomplete and limiting your search to control technologies found in the RBLC is not acceptable to most regulators.

South Coast Air Quality Management District (SCAQMD)

The South Coast Air Quality Management District (SCAQMD) of southern California posts their BACT decisions online and is a good resource to use to identify control technologies applicable to the emission unit, or similar emission units. Simply follow the above link to their website and search through the BACT decisions.

SCAQMD BACT Database Search Result

SCAQMD BACT Database Search Result

In this example, the emission unit (or process) is a system for manufacturing fiber-impregnated material. The control technology that was considered BACT in this case was a baghouse for the control of particulate emissions from the process coupled with the use of zero-VOC materials.

Bay Area Air Quality Management District (BAAQMD)

BAAQMD BACT Workbook Search Result

BAAQMD BACT Workbook Search Result

The identification of applicable control technologies is often a difficult and time consuming task. The reason for this is that, in many cases, the expectations of the regulator go beyond simple online database and resource searches. If you are required to perform a BACT Analysis, I suggest you discuss available resources with your permitting engineer because in most cases they will be the one accepting or denying your analysis.

If you would like assistance with completing your BACT Analysis, I have the project experience and proprietary tools that make the process as quick and seamless as possible. Please feel free to contact me at any time for a FREE BACT Analysis Consultation.

bmogan BACT Process , , , ,

BACT Analysis Requirement: Uncommon Processes and Equipment

June 4th, 2009
What type of emission units require a Best Available Control Technology Analysis (BACT Analysis)?  There are a number of online resources, such as the EPA’s RACT/BACT/LAER Clearinghouse (RBLC), available that contain information related to BACT decisions for processes or emissions equipment at facilities across the United States. These will be discussed in future articles. It is important to note, however, that generally the requirement to perform a BACT Analysis is not dependant upon the type of emission unit, but rather the type of pollutant and quantity of emissions from the process or piece of equipment.

 

The BACT Analysis requirement is common for the utility industry (e.g., a turbine at an electrical generating facility). Here are a few more uncommon cases where a BACT Analysis was required:

Tub-Grinder with 325-HP Diesel Engine

Tub-Grinder with 325-HP Diesel Engine

This Tub-Grinder, used to grind municipal waste at a landfill,
was subject to a BACT Analysis because of its potential 
emissions of nitrogen oxides (NOx).

Fuel Cell Test Stand

Fuel Cell Test Stand

 Fuel cell test stands requiring a BACT Analysis for their potential
hydrogen emissions.
www.eutech-scientific.de

 It is important to consider all applicable regulations when determining whether or not you must perform a BACT Analysis. Again, the requirement is not dependant upon the process or equipment, but the type and amount of pollutant being emitted from the process or equipment. If you require assistance determining whether or not your project is subject to a BACT Analysis, or you need help with the BACT Analysis process, click here.

bmogan BACT Projects, General , , , , ,

The BACT Analysis Guide: Regulatory Applicability

May 28th, 2009

Why might a Best Available Control Technology Analysis (BACT Analysis) apply to my project? The requirement to perform a BACT Analysis applies to significant emissions of New Source Review (NSR) Pollutants from new sources and from modifications of existing sources. The applicable federal regulations are found at 40 CFR 52.21(j). The BACT Analysis requirement is also covered by regulations for State Implementation Plan (SIP) approval of a state Prevention of Significant Deterioration (PSD) program at 40 CFR 51.166(j).

Natural Gas Fired Boiler

Natural Gas Fired Boiler

The BACT Requirement applies to new sources, or modifications of existing sources, which emit the following NSR pollutants:

  • Pollutants with a National Ambient Air Quality Standards (NAAQS), also known as criteria pollutants, which include:
    • Ozone
    • Carbon Monoxide
    • Particulate Matter
    • Sulfur Dioxide
    • Lead
    • Nitrogen Oxide
  • Other pollutants including sulfuric acid mist, hydrogen sulfide, etc.
  • Note that some states, such as Connecticut require BACT for ANY pollutant

The federal regulations require that “Major Sources” and “Major Modifications to existing sources” perform a BACT Analysis. However, some states have more stringent requirements. The following are a few examples:

  • Connecticut
    • Potential emissions greater than the threshold for major sources and major modifications
    • Potential emissions greater than 15-tons per year from ANY new emission unit or modification to existing emission units (not just major sources)
  • South Carolina
    • Any new construction when the net VOC emissions increase is greater than 100-tons per year

For your state’s specific BACT requirements, you should check with your local regulator (City, County, State).

bmogan BACT Regulations, General , , , , , ,